Academic Radiology
Volume 10, Issue 1 , Pages 25-31, January 2003

Validation of the Summary ROC for Diagnostic Test Meta-Analysis:

A Monte Carlo Simulation

  • Matthew D Mitchell, PhD

      Affiliations

    • Corresponding Author InformationTechnology Assessment Group, ECRI, 5200 Butler Pike, Plymouth Meeting, PA 19462

Technology Assessment Group, ECRI, 5200 Butler Pike, Plymouth Meeting, PA 19462, USA

Received 5 August 2002; received in revised form 26 August 2002; accepted 26 August 2002.

Abstract 

Rationale and Objectives

The author performed this study to test a technique for validating the logit regression method for summary receiver operating characteristic (ROC) meta-analysis, perform initial validation studies, and identify areas for further investigation.

Materials and Methods

Monte Carlo simulation was performed by using a custom macro program for a personal computer spreadsheet. The program creates simulated data sets based on user-specified parameters, performs a meta-analysis on the data sets, and logs the results so the accuracy and variability of the method can be measured. The program can also be used to measure the effects of changes in study design and meta-analysis parameters.

Results

For the base case of a small meta-analysis (10 studies) of small trials (mean, 50 patients), the meta-analysis results closely matched the input sensitivity and specificity when they were less than 80%. Systematic errors, if any, were small. At sensitivities and specificities greater than 80%, the true sensitivity or specificity was underestimated by up to 2% in the meta-analysis. Confidence intervals calculated with the summary ROC curve were reasonably conservative, although they too fell below the true results when sensitivity or specificity was greater than 80%. The underestimation was eliminated when the simulation was repeated for a much larger trial (mean, 1,000 cases per study)\Meven with a sensitivity and specificity of 98%.

Conclusion

The Littenberg-Moses method for summary ROC meta-analysis is effective for obtaining an accurate summary estimate of diagnostic test performance, although the continuity correction introduces a small downward bias in the meta-analysis of small trials.

Keywords:  Data analysis, receiver operating characteristic curve (ROC), meta-analysis

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1076-6332(03)80784-5

doi:10.1016/S1076-6332(03)80784-5

Academic Radiology
Volume 10, Issue 1 , Pages 25-31, January 2003