Academic Radiology
Volume 13, Issue 1 , Pages 14-23, January 2006

Use of an Optical Flow Method for the Analysis of Serial CT Lung Images1

Hospital of the University of Pennsylvania, Department of Radiology/1 Silverstein, 3400 Spruce Street, Philadelphia, PA 19104.

Received 31 March 2005; received in revised form 2 September 2005; accepted 4 September 2005.

Rationale and Objectives

Serial CT lung studies are difficult to compare due to misregistration between image sets. An optical flow method (OFM) was adapted for use on CT lung images to register images and visualize changes between studies. Three applications were investigated: lung nodule assessment; evaluation of pulmonary enhancement; and functional changes due to air trapping.

Materials and Methods

From an initial clinical study, a follow-up study was created by digitally manipulating the images to simulate patient positioning errors and nodule growth. Nodule growth was measured from the temporal subtraction of registered images. In application to the assessment of pulmonary enhancement, pre and postcontrast images from a patient with acute pulmonary embolism (PE) were registered. A map of the perfused blood volume was computed from the ratio of aligned lung volumes. Functional changes in the lung were demonstrated using images from a patient with air trapping. End-inspiratory and end-expiratory volumes were aligned and displacement fields estimated using the OFM. Principal strains were computed from the displacement fields.

Results

All image volumes were aligned with at least 0.95 correlation. OFM estimates of displacement showed excellent agreement with the prescribed displacements with 0.33 pixel RMS error. Nodule growth was evident in the presence of significant positioning errors. In the PE case, enhancement ratios indicated a hypoperfused area consistent with an occlusive hypodense filling defect. For the air trapping case, a strain map showed functional changes along the interface of the air trap.

Conclusions

The OFM can facilitate the detection and quantification of changes between serial CT lung studies.

Key Words:  Computed tomography (CT) , lung , nodule , perfusion , registration

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 30.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1076-6332(05)00801-9

doi:10.1016/j.acra.2005.09.081

Academic Radiology
Volume 13, Issue 1 , Pages 14-23, January 2006