Physical Evaluation of the Weighted Feldkamp Algorithms Applied to the 256-Detector Row CT Scanner for Volumetric Cine Imaging

  • Shinichiro Mori, PhD, MPH

      Affiliations

    • Department of Medical Physics and Medical Imaging, National Institute of Radiological Sciences, 4-9-1 Anagawa Inage-IW, Chiba 263-8555, Japan
    • Corresponding Author InformationAddress correspondence to: S.M.
  • ,
  • Masahiro Endo, PhD, MPH

      Affiliations

    • Department of Radiology, Tokyo Women’s Medical University School of Medicine, Tokyo, Japan.
  • ,
  • Chisato Kondo, MD

      Affiliations

    • Department of Radiology, Tokyo Women’s Medical University School of Medicine, Tokyo, Japan.
  • ,
  • Shuji Tanada, MD

      Affiliations

    • Department of Radiology, Tokyo Women’s Medical University School of Medicine, Tokyo, Japan.

Received 6 June 2005 ,Revised 3 March 2006 ,Accepted 3 March 2006.

References 

  1. Parker DL . Optimal short scan convolution reconstruction for fanbeam CT . Med Phys . 1982;9:254–257
  2. Flohr T , Ohnesorge B . Heart-rate adaptive optimization of spatial and temporal resolution for ECG-gated multi-slice spiral CT of the heart . J Comput Assist Tomogr . 2001;25:907–923
  3. Kachelrieß M , Ulzheimer S , Kalender WA . ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart . Med Phys . 2000;27:1881–1902
  4. Bruder H , Stierstorfer K , Ohnesorge B , et al.   A novel reconstruction scheme for cardiac volume imaging with MSCT providing cone correction . Proc SPIE . 2001;4684:60–71
  5. Endo M , Mori S , Tsunoo T , et al.   Development and performance evaluation of the first model of 4D CT-scanner . IEEE Trans Nucl Sci . 2003;50:1667–1671
  6. Feldkamp LA , Davis LC , Kress JW . Practical cone-beam algorithm . J Opt Soc Am . 1984;1:612–619
  7. Mori S , Endo M , Tsunoo T , et al.   Physical performance evaluation of a 256-detector row CT-scanner for 4-dimensional imaging . Med Phys . 2004;31:1348–1356
  8. Saito Y , Aradate H , Igarashi K , et al.   Large area 2-dimensional detector for real-time 3-dimensional CT (4D CT) . Proc SPIE . 2001;4320:775–782
  9. Silver MD . A method for including redundant data in computed tomography . Med Phys . 2000;27:773–774
  10. Taguchi K . Temporal resolution and the evaluation of candidate algorithms for four-dimensional CT . Med Phys . 2003;30:640–650
  11. Taguchi K , Anno H . High temporal resolution for multislice helical computed tomography . Med Phys . 2000;27:861–872
  12. Kudo H , Saito Y . Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits . IEEE Trans Med Imaging . 1994;13:196–211
  13. Hu H . A new cone beam reconstruction algorithm and its application to circular orbits . Proc SPIE . 1994;2163:223–234
  14. Hsieh J . Nonstationary noise characteristics of the helical scan and its impact on image quality and artifact . Med Phys . 1997;24:1375–1384
  15. Yu L , Pan X . Half-scan fan-beam computed tomography with improved noise and resolution properties . Med Phys . 2003;30:2629–2637
  16. Kudo H , Saito T . Three-dimensional helical-scan computed tomography using cone-beam projections . Syst Comput Jpn . 2002;23:75–82
  17. Tuy HK . An inversion fomula for cone-beam reconstruction . SIAM J Math . 1983;43:546–552
  18. Smith BD . Image reconstruction methods . IEEE Trans Med Imaging . 1985;4:14–25
  19. Grangeat P . Mathematical framework of cone-beam 3D reconstruction via the first derivative of the Radon transform . In:  Herman GT ,  Louis AK ,  Natterer F editor. Mathematical Methods in Tomography, Lecture Notes in Mathematics 1497 . New York: Springer-Verlag; 1991;p. 66–97
  20. Kachelrieß M , Schaler S , Kalender WA . Advanced single-slice rebining in cone-beam spiral CT . Med Phys . 2000;27:754–772
  21. Schaller S , Noo F , Sauer F , Tam KC , Lauritsh G , Flohr T . Exact Radon rebinning algorithm for the long object problem in helical cone-beam CT . IEEE Trans Med Imaging . 2000;19:361–375
  22. Mori S , Obata T , Kishimoto R , et al.   Clinical potentials for dynamic contrast-enhanced hepatic volumetric cine imaging with the prototype 256-detector row CT-scanner . AJR Am J Roentegenol . 2005;185:253–256

PII: S1076-6332(06)00170-X

doi: 10.1016/j.acra.2006.03.002

Academic Radiology
Volume 13, Issue 6 , Pages 701-712 , June 2006