Academic Radiology
Volume 15, Issue 1 , Pages 62-70, January 2008

Comparison of Low-Dose CT and MR for Measurement of Intra-Abdominal Adipose Tissue:1

A Phantom and Human Study

  • Dae Young Yoon, MD, PhD

      Affiliations

    • Department of Radiology, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, 445 Gil-dong Kangdong-Gu, Seoul, 134-701, Korea
    • Corresponding Author InformationAddress correspondence to: D.Y.Y.
  • ,
  • Jeung Hee Moon, MD

      Affiliations

    • Department of Radiology, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, 445 Gil-dong Kangdong-Gu, Seoul, 134-701, Korea
  • ,
  • Heon Kyu Kim, MD, PhD

      Affiliations

    • Department of Internal Medicine, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, 445 Gil-dong Kangdong-Gu, Seoul, 134-701, Korea.
  • ,
  • Chul Soon Choi, MD, PhD

      Affiliations

    • Department of Radiology, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, 445 Gil-dong Kangdong-Gu, Seoul, 134-701, Korea
  • ,
  • Suk Ki Chang, MD

      Affiliations

    • Department of Radiology, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, 445 Gil-dong Kangdong-Gu, Seoul, 134-701, Korea
  • ,
  • Eun Joo Yun, MD, PhD

      Affiliations

    • Department of Radiology, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, 445 Gil-dong Kangdong-Gu, Seoul, 134-701, Korea
  • ,
  • Young Lan Seo, MD, PhD

      Affiliations

    • Department of Radiology, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, 445 Gil-dong Kangdong-Gu, Seoul, 134-701, Korea

Received 14 June 2007; accepted 13 July 2007.

Rationale and Objectives

The aim of this study was to determine the accuracy and reproducibility of low-dose computed tomography (CT) and magnetic resonance (MR) for abdominal adipose tissue quantification on phantom and human studies.

Materials and Methods

An adiposity phantom (with known internal/external oil volumes) was scanned at three different tube voltages (140, 120, and 90 kVp) using a 16-detector row CT scanner and was imaged using a T1-weighted spin echo MR sequence. For human studies, whole-volume coverage of the abdomen was obtained using CT (at 140 and 90 kVp) and T1-weighted spin echo MR imaging from five obese male volunteers (mean age, 40.6 years; mean body mass index, 30.2). The volumes of total, visceral, and subcutaneous adipose tissues (TAT, VAT, and SAT, respectively) were calculated independently by two radiologists for each CT scan and MR imaging using a computer-aided semiautomatic program.

Results

The estimated radiation dose could be reduced by approximately 75% with a 90-kVp protocol as compared with the 140-kVp protocol. Phantom studies showed that there was no statistically significant difference between the four methods in estimating the percentage predicted of the true volumes (measurement errors <4% for all methods, P > .05). In human studies, we found no statistically significant difference between the three methods in TAT, VAT, and SAT volumes (P > .05). Inter- and intraobserver reproducibilities of the CT volume estimates using the 90-kVp protocol were better than those obtained from MR imaging (κ > 0.9 versus 0.4–0.5; coefficient of variation < 1% versus 15–22%).

Conclusion

Low-dose CT provides accurate and reproducible measurement of abdominal adipose tissue volumes with a relevant dose reduction.

Key Words: Computed tomography (CT), magnetic resonance imaging (MRI), fat quantification, dose reduction, phantom study

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

1 Supported by a grant no. 01-2007-09 from the Hallym University Medical Center Research Fund.

PII: S1076-6332(07)00404-7

doi:10.1016/j.acra.2007.07.013

Academic Radiology
Volume 15, Issue 1 , Pages 62-70, January 2008