Academic Radiology
Volume 16, Issue 2 , Pages 172-180 , February 2009

Computer-aided Detection of Endobronchial Valves Using Volumetric CT

Received 19 April 2008 ,Accepted 14 July 2008.

References 

  1. Toma T, Hopkinson N, Hillier J, Hansell D, Morgan C, Goldstraw P, et al. Bronchoscopic volume reduction with valve implants in patients with severe emphysema. Lancet. 2003;361:931–933
  2. Wan IYP, Toma TP, Geddes DM, et al. Bronchoscopic lung volume reduction for end-stage emphysema: report on the first 98 patients. Chest. 2006;129:518–526
  3. Yim A, Hwong T, Lee T, Li W, Lam S, Yeung T, et al. Early results of endoscopic lung volume reduction for emphysema. J Thorac Cardiovasc Surg. 2004;127:1564–1573
  4. Maxfield RA. New and emerging minimally invasive techniques for lung volume reduction. Chest. 2004;125:777–783
  5. Harris E, McNair H, Evans P. Feasibility of fully automated detection of fiducial markers implanted into the prostate using electronic portal imaging: A comparison of methods. Int J Radiation Oncology Biol Phys. 2006;66:1263–1270
  6. van der Weide R, Bakker C, Viergever M. Localization of intravascular devices with paramagnetic markers in MR images. IEEE Trans Med Imaging. 2001;20:1061–1071
  7. Brown MS, Goldin JG, McNitt-Gray MF, Greaser LE, Sapra A, Li KT, et al. Knowledge-based segmentation of thoracic CT images for assessment of split lung function. Med Phys. 2000;27:592–598
  8. Abramson Y, Freund Y. SEmi-automatic VIsuaL LEarning (SEVILLE): a tutorial on active learning for visual object recognition. IEEE Computer Society Conference on Computer Vision and Pattern Recognition. 2005;
  9. Viola P, Jones M. Rapid object detection using a boosted cascade of simple features. IEEE Computer Society Conference on Computer Vision and Pattern Recognition. 2001;
  10. Duda RO, Hart PE, Stork DG. Pattern classification. 2nd ed.. New York, NY: John Wiley and Sons; 2001;
  11. Ochs R, Goldin J, Abtin F, Kim HJ, Brown K, Batra P, et al. Automated classification of lung bronchovascular anatomy in CT using AdaBoost. Med Image Anal. 2007;11:315–324
  12. Food and Drug Administration. Critical Path Opportunities List. http://www.fda.gov/oc/initiatives/criticalpath/reports/opp_list.pdf2006;Accessed September 29, 2008
  13. Das KM, El-Menyar AA, Salam AM, Singh R, Dabdoob WAK, Albinali HA, et al. Contrast-enhanced 64-section coronary multidetector CT angiography versus conventional coronary angiography for stent assessment. Radiology. 2007;245:424–432

1 This study was provided by University of California Discovery Grant IT106-10158 in collaboration with Broncus Technologies, Inc., Mountain View, CA, and Emphasys Medical Inc., Redwood City, CA.

PII: S1076-6332(08)00407-8

doi: 10.1016/j.acra.2008.07.009

Academic Radiology
Volume 16, Issue 2 , Pages 172-180 , February 2009