Academic Radiology
Volume 16, Issue 1 , Pages 22-27, January 2009

Lung Motion and Volume Measurement by Dynamic 3D MRI Using a 128-Channel Receiver Coil1

  • Junichi Tokuda, PhD

      Affiliations

    • Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, MA 02115
  • ,
  • Melanie Schmitt, PhD

      Affiliations

    • Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA
  • ,
  • Yanping Sun, PhD

      Affiliations

    • Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, MA 02115
  • ,
  • Samuel Patz, PhD

      Affiliations

    • Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, MA 02115
  • ,
  • Yi Tang, MD

      Affiliations

    • Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, MA 02115
  • ,
  • Carolyn E. Mountford, PhD

      Affiliations

    • Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, MA 02115
  • ,
  • Nobuhiko Hata, PhD

      Affiliations

    • Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, MA 02115
  • ,
  • Lawrence L. Wald, PhD

      Affiliations

    • Harvard-MIT Division of Health Sciences Technology, Cambridge, MA
  • ,
  • Hiroto Hatabu, MD, PhD

      Affiliations

    • Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, MA 02115
    • Corresponding Author InformationAddress correspondence to: H.H.

Received 21 April 2008; accepted 7 July 2008.

Rationale and Objectives

The authors present their initial experience using a 3-T whole-body scanner equipped with a 128-channel coil applied to lung motion assessment. Recent improvements in fast magnetic resonance imaging (MRI) technology have enabled several trials of free-breathing three-dimensional (3D) imaging of the lung. A large number of image frames necessarily increases the difficulty of image analysis and therefore warrants automatic image processing. However, the intensity homogeneities of images of prior dynamic 3D lung MRI studies have been insufficient to use such methods. In this study, initial data were obtained at 3 T with a 128-channel coil that demonstrate the feasibility of acquiring multiple sets of 3D pulmonary scans during free breathing and that have sufficient quality to be amenable to automatic segmentation.

Materials and Methods

Dynamic 3D images of the lungs of two volunteers were acquired with acquisition times of 0.62 to 0.76 frames/s and an image matrix of 128 × 128, with 24 to 30 slice encodings. The volunteers were instructed to take shallow and deep breaths during the scans. The variation of lung volume was measured from the segmented images.

Results

Dynamic 3D images were successfully acquired for both respiratory conditions for each subject. The images showed whole-lung motion, including lifting of the chest wall and the displacement of the diaphragm, with sufficient contrast to distinguish these structures from adjacent tissues. The average time to complete segmentation for one 3D image was 4.8 seconds. The tidal volume measured was consistent with known tidal volumes for healthy subjects performing deep-breathing maneuvers. The temporal resolution was insufficient to measure tidal volumes for shallow breathing.

Conclusion

This initial experience with a 3-T whole-body scanner and a 128-channel coil showed that the scanner and imaging protocol provided dynamic 3D images with spatial and temporal resolution sufficient to delineate the diaphragmatic domes and chest wall during active breathing. In addition, the intensity homogeneities and signal-to-noise ratio were adequate to perform automatic segmentation.

Key Words: Lung, magnetic resonance imaging, image segmentation, lung volume measurement

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

1 This work was supported in part by grant R21CA116271-02 from the National Institutes of Health, Bethesda, MD.

PII: S1076-6332(08)00453-4

doi:10.1016/j.acra.2008.07.021

Academic Radiology
Volume 16, Issue 1 , Pages 22-27, January 2009