Academic Radiology
Volume 17, Issue 1 , Pages 39-47, January 2010

Comparison of 2D and 3D Views for Evaluation of Flat Lesions in CT Colonography

  • Antonella Lostumbo, MD

      Affiliations

    • Department of Radiology, University of Chicago Hospitals, MC2026, 5841 S. Maryland Ave, Chicago, IL 60637
  • ,
  • Christian Wanamaker, MD, PhD

      Affiliations

    • Department of Radiology, University of Chicago Hospitals, MC2026, 5841 S. Maryland Ave, Chicago, IL 60637
    • University of Illinois-Chicago, College of Medicine, Chicago, IL
  • ,
  • Joy Tsai, MD

      Affiliations

    • Department of Radiology, University of Chicago Hospitals, MC2026, 5841 S. Maryland Ave, Chicago, IL 60637
    • University of Illinois-Chicago, College of Medicine, Chicago, IL
  • ,
  • Kenji Suzuki, PhD

      Affiliations

    • Department of Radiology, University of Chicago Hospitals, MC2026, 5841 S. Maryland Ave, Chicago, IL 60637
    • Schwab Rehabilitation Hospital, Chicago, IL
  • ,
  • Abraham H. Dachman, MD

      Affiliations

    • Department of Radiology, University of Chicago Hospitals, MC2026, 5841 S. Maryland Ave, Chicago, IL 60637
    • Corresponding Author InformationAddress correspondence to: A.H.D.

Received 20 March 2009; accepted 9 July 2009. published online 07 September 2009.

Rationale and Objectives

Flat lesions in the colon may result in false-negative computed tomography colonography interpretations. It is unknown whether flat lesions are better measured on two-dimensional (2D) or three-dimensional (3D) images and which settings are optimal for enhanced reproducibility and decreased variability. We evaluated these factors to determine whether 2D or 3D is best for flat lesion measurements.

Methods and Materials

Eighty-eight lesions in 66 patients from a previously published clinical trial were analyzed. Lesions were viewed with four methods including 2D at three window/level settings and 3D endoluminal view. Lesions in either supine or prone were counted as one dataset. Long axis and height were measured. Criteria of “height” (≤3 mm high) or “ratio” (height ≤half the long axis) were applied. A subset of lesions was subject to inter- and intra-observer variability analysis.

Results

With the “height” criterion, more datasets were classified as flat in 2D flat (n = 76), 2D soft tissue (n = 82), and 3D (n = 73) views than in the 2D lung (n = 49) view. If long axis is used as the key metric, endoluminal 3D (12.1%) views significantly showed the least inter-observer variability compared to lung (18.9%) or soft tissue (20.2%) views. Intra-observer variability was low overall for all methods.

Conclusion

When characterizing lesions as flat, a consistent viewing method should be used. To minimize inter-observer variability (such as when following a patient over time), it is best to use the ratio criterion for flat lesion definition incorporating the single longest dimension on 3D views as the key metric.

Key Words: CT colonography, colon, screening, computed tomography, virtual colonoscopy

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1076-6332(09)00400-0

doi:10.1016/j.acra.2009.07.004

Academic Radiology
Volume 17, Issue 1 , Pages 39-47, January 2010