Academic Radiology
Volume 16, Issue 12 , Pages 1502-1508, December 2009

Peripheral Intravenous Power Injection of Iodinated Contrast Media:

The Impact of Temperature on Maximum Injection Pressures at Different Cannula Sizes

Department of Radiology, University Hospital Erlangen, Maximiliansplatz 1, D-91054 Erlangen, Germany

Received 27 April 2009; accepted 24 July 2009.

Rationale and Objectives

Modern computed tomographic scanners and examination protocols often require high injection rates of iodinated contrast media (CM). The purpose of this study was to investigate the maximum injection pressures (MIPs) with different CM at different temperatures in the most common intravenous cannula (IVC) sizes.

Materials and methods

Three IVC sizes, 22, 20, and 18 gauge, were evaluated. All examinations were performed with a pressure-limited (300 psi) power injector. The MIPs of three different CM (Solutrast 300, Imeron 350, and Imeron 400) were measured at room temperature (20°C) and at 37°C using increasing flow rates (1–9 mL/s). The intactness of the IVCs was checked after injection.

Results

Heating the CM led to reductions in injection pressures (P < .001). Using constant flow rates, the difference in MIP between 20-gauge and 22-gauge IVCs was higher than that between 20-gauge and 18-gauge IVCs. By heating the CM, the manufacturer's suggested operating pressure limit was exceeded at higher flow rates, such as with an 18-gauge cannula at 8 mL/s instead of 6 mL/s using warmed iomeprol 400. Even with pressures of up to 159.7 psi, none of the IVCs ruptured.

Conclusions

Heating of CM effectively reduces MIPs using power injection in common IVCs. Although the manufacturer's suggested MIP was exceeded at higher flow rates, safe CM injection seems to be possible even in small cannulas using power injection. The compilation of the obtained data is meant to serve as guidance for future decisions on parameters of the power injection of iodinated CM.

Key Words: Iodinated contrast media, intravenous cannula, power injection, injection pressure

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1076-6332(09)00430-9

doi:10.1016/j.acra.2009.07.026

Academic Radiology
Volume 16, Issue 12 , Pages 1502-1508, December 2009