Academic Radiology
Volume 17, Issue 2 , Pages 188-193, February 2010

Dynamic Contrast Enhancement of Experimental Glioma:

An Intra-individual Comparative Study to Assess the Optimal Time Delay

  • Tobias Engelhorn, MD

      Affiliations

    • Department of Neuroradiology, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen, Germany
    • Corresponding Author InformationAddress correspondence to: T.E.
  • ,
  • Marc A. Schwarz, PhD

      Affiliations

    • Department of Neuroradiology, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen, Germany
  • ,
  • Ilker Y. Eyupoglu, MD

      Affiliations

    • Department of Neurosurgery, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen, Germany
  • ,
  • Stephan P. Kloska, MD

      Affiliations

    • Department of Neuroradiology, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen, Germany
  • ,
  • Tobias Struffert, MD

      Affiliations

    • Department of Neuroradiology, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen, Germany
  • ,
  • Arnd Doerfler, MD

      Affiliations

    • Department of Neuroradiology, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen, Germany

Received 13 July 2009; accepted 14 August 2009. published online 12 November 2009.

Rationale and Objectives

The aim of this study was to compare tumor signal and contrast media uptake characteristics on contrast-enhanced T1-weighted sequences at 3 Tesla over 30 minutes after double-dose administration of different contrast agents in an animal model of brain glioma.

Materials and Methods

Nine rats underwent magnetic resonance imaging (MRI) after stereotactic F98 glioma cell implantation before and repetitively for 30 minutes after injection of gadobutrol, gadopentetate, and gadobenate, respectively. Signal-to-noise ratio (SNR) and tumor contrast-to-noise ratio (CNR) were evaluated and MRI-derived tumor volumes were compared to histology.

Results

Postcontrast tumor SNR and CNR peaked at 4 minutes after contrast application. While contrast-enhancement within the tumor was fading, tumor volume increased by continuous contrast-uptake of peripheral parts between 4 minutes (137 ± 29 mm3, 126 ± 16 mm3, 141 ± 24 mm3) and 20 minutes (182 ± 35 mm3, 164 ± 32 mm3, 191 ± 25 mm3), respectively. At 8 and 12 minutes, 84% and 91% of the tumor volume were definable, respectively.

Conclusion

Optimal correlation between MRI-derived tumor volume and histology is achieved by imaging up to 20 minutes after contrast application. At 4 minutes (this delay is mostly used in clinical routine), only 75% of the enhancing tumor volume is assessable. A delay of 8 minutes already reveals 84% of the tumor and seems to be a practical clinical compromise.

Key Words: Glioma, contrast media, 3 Tesla, MRI, rat

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1076-6332(09)00504-2

doi:10.1016/j.acra.2009.08.014

Academic Radiology
Volume 17, Issue 2 , Pages 188-193, February 2010