Academic Radiology
Volume 17, Issue 3 , Pages 298-308 , March 2010

Diagnostic Performance of a Prototype Dual-Energy Chest Imaging System: ROC Analysis

  • Hany Kashani, MD

      Affiliations

    • Ontario Cancer Institute, Princess Margaret Hospital, University Health Network, Toronto, Ontario, Canada
    • Institute of Medical Science, University of Toronto, Toronto, Ontario, Canada
  • ,
  • Carlos A. Varon, BSc

      Affiliations

    • Ontario Cancer Institute, Princess Margaret Hospital, University Health Network, Toronto, Ontario, Canada
  • ,
  • Narinder S. Paul, MD

      Affiliations

    • Department of Medical Imaging, University Health Network and Mt. Sinai Hospital, Toronto, Ontario, Canada
  • ,
  • Grace J. Gang, BASc

      Affiliations

    • Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
  • ,
  • Rich Van Metter, PhD

      Affiliations

    • Carestream Health Inc., Rochester, NY
  • ,
  • John Yorkston, PhD

      Affiliations

    • Carestream Health Inc., Rochester, NY
  • ,
  • Jeffrey H. Siewerdsen, PhD

      Affiliations

    • Ontario Cancer Institute, Princess Margaret Hospital, University Health Network, Toronto, Ontario, Canada
    • Institute of Medical Science, University of Toronto, Toronto, Ontario, Canada
    • Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
    • Department of Biomedical Engineering, Johns Hopkins University, Traylor Building, Room #718, 720 Rutland Avenue, Baltimore MD 21205
    • Corresponding Author InformationAddress correspondence to: J.H.S.

Received 13 July 2009 ,Accepted 10 October 2009.

References 

  1. Kido S, Kuriyama K, Kuroda C, et al. Detection of simulated pulmonary nodules by single-exposure dual-energy computed radiography of the chest: effect of a computer-aided diagnosis system. Eur J Radiol. 2002;44:205–209
  2. Samei E, Flynn MJ. An experimental comparison of detector performance for direct and indirect digital radiography systems. Med Phys. 2003;30:608–622
  3. Antonuk LE, El-Mohri Y, Siewerdsen JH, et al. Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation. Med Phys. 1997;24:51–70
  4. Zhao W, Blevis I, Germann S, et al. Digital radiology using active matrix readout of amorphous selenium: construction and evaluation of a prototype real-time detector. Med Phys. 1997;24:1834–1843
  5. Sonoda M, Takano M, Miyahara J, et al. Computed radiography utilizing scanning laser stimulated luminescence. Radiology. 1983;148:833–838
  6. Samei E, Flynn MJ, Eyler WR. Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs. Radiology. 1999;213:727–734
  7. Szucs-Farkas Z, Patak MA, Yuksel-Hatz S, et al. Single-exposure dual-energy subtraction chest radiography: detection of pulmonary nodules and masses in clinical practice. Eur Radiol. 2008;18:24–31
  8. Ricke J, Fischbach F, Freund T, et al. Clinical result of Csl-detector-based dual-exposure dual-energy subtraction chest radiography. Eur Radiol. 2003;13:2577–2582
  9. Ide K, Mogami H, Murakami T, et al. Detection of lung cancer using single-exposure dual-energy subtraction chest radiography. Radiat Med. 2007;25:195–201
  10. Uemura M, Miyagawa M, Yasuhara Y, et al. Clinical evaluation of pulmonary nodules with Dual-exposure Dual-energy subtraction chest radiography. Radiat Med. 2005;23:391–397
  11. Sabol J, Avinash G, Nicolas F, et al. The development and characterization of a dual-energy subtraction imaging system for chest radiography based on CsI: TI amorphous silicon flat panel technology. Proc SPIE. 2001;4320:399–408
  12. Tagashira H, Arakawa K, Yoshimoto M, et al. Detectability of lung nodules using flat panel dual energy subtraction by two shot method: evaluation by ROC method. Eur J Radiol. 2007;64:279–284
  13. Fraser R, Hickey N, Niklason L, et al. Calcification in pulmonary nodules: detection with dual-energy digital radiography. Radiology. 1986;160:595–601
  14. Kelcz F, Zink F, Peppler W, et al. Conventional chest radiography vs. dual-energy computed radiography in the detection and characterization of pulmonary nodules. AJR Am J Roentgenol. 1994;162:271–278
  15. Rühl R, Wozniak MM, Werk M, et al. CsI-detector-based dual-exposure dual energy in chest radiography for lung nodule detection: results of an international multicenter trial. Eur Radiol. 2008;18:1831–1839
  16. Kashani H, Gang JG, Shkumat NA, et al. Development of a high-performance dual-energy chest imaging system: initial investigation of diagnostic performance. Acad Radiol. 2009;16:464–476
  17. Shkumat NA, Siewerdsen JH, Dhanantwari AC, et al. Optimization of image acquisition techniques for dual-energy imaging of the chest. Med Phys. 2007;34:3904–3915
  18. Richard S, Siewerdsen JH. Cascaded systems analysis of noise reduction algorithms in dual-energy imaging. Med Phys. 2008;35:586–601
  19. Siewerdsen J, Shkumat N, Dhanantwari A, et al. High performance dual-energy imaging with a flat panel detector: imaging physics from blackboard to benchtop to bedside. Proc SPIE medical imaging. Physics of Medical Imaging. 2006;6142:61421E-1–61421E-10
  20. Shkumat NA, Siewerdsen JH, Dhanantwari AC, et al. Cardiac gating with a pulse oximeter for dual-energy imaging. Med Phys. 2008;53:6097–6112
  21. Gang J, Varon C, Kashani H, et al. Multiscale deformable registration for dual-energy x-ray imaging. Med Phys. 2009;36:351–363
  22. Kalender WA, Klotz E, Kostaridou L. An algorithm for noise suppression in dual energy CT material density images. IEEE Trans Med Imaging. 1988;7:218–224
  23. McCollough CH, Van Lysel MS, Peppler WW, et al. A correlated noise reduction algorithm for dual-energy digital subtraction angiography. Med Phys. 1989;16:873–880
  24. Johns PC, Yaffe MJ. Theoretical optimization of dual-energy x-ray imaging with application to mammography. Med Phys. 1985;12:289–296
  25. Obuchowski NA. ROC Analysis. AJR Am J Roentgenol. 2005;184:364–372
  26. Dorfman DD, Alf E. Maximum likelihood estimation of parameters of signal detection theory—a direct solution. Psychometrika. 1968;33:117–124
  27. Shah PK, Austin JH, White CS, et al. Missed non-small cell lung cancer: radiographic findings of potentially resectable lesions evident only in retrospect. Radiology. 2003;226:235–241

 Supported by a grant from the National Institutes of Health (R01-CA-112163) and research collaboration with Carestream Health Inc. (Rochester, NY).

PII: S1076-6332(09)00584-4

doi: 10.1016/j.acra.2009.10.012

Academic Radiology
Volume 17, Issue 3 , Pages 298-308 , March 2010