Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribe:
Subscribe to Academic RadiologyReferences
Accessed from: https://www.acrdsi.org/. Accessed at: July 1, 2021.
- Trends and patterns in the use of computed tomography in children and young adults in Catalonia - results from the EPI-CT study.Pediatr Radiol. 2016; 46: 119-129https://doi.org/10.1007/s00247-015-3434-5
- Computed tomography–an increasing source of radiation exposure.N Engl J Med. 2007; 357: 2277-2284https://doi.org/10.1056/NEJMra072149
- Strategies for reducing radiation dose in CT.Radiol Clin North Am. 2009; 47: 27-40https://doi.org/10.1016/j.rcl.2008.10.006
- Strategies for CT radiation dose optimization.Radiology. 2004; 230: 619-628https://doi.org/10.1148/radiol.2303021726
- Radiation dose reduction with sinogram affirmed iterative reconstruction technique for abdominal computed tomography.J Comput Assist Tomogr. 2012; 36: 339-346https://doi.org/10.1097/RCT.0b013e31825586c0
- Competitive performance of a modularized deep neural network compared to commercial algorithms for low-dose CT image reconstruction.Nat Mach Intell. 2019; 1: 269-276https://doi.org/10.1038/s42256-019-0057-9
- Deep learning for biomedical image reconstruction: a survey.Artif Intell Rev. 2021; 54: 215-251
- Deep learning: A primer for radiologists.Radiographics. 2017; 37: 2113-2131https://doi.org/10.1148/rg.2017170077
- CT dose reduction and dose management tools: overview of available options.Radiographics. 2006; 26: 503-512https://doi.org/10.1148/rg.262055138
- In-plane shielding for CT: effect of off-centering, automatic exposure control and shield-to-surface distance.Korean J Radiol. 2009; 10: 156-163https://doi.org/10.3348/kjr.2009.10.2.156
- Influence of patient centering on CT dose and image noise.Medical Physics. 2007; 34: 3093-3101
- Artificial intelligence in diagnostic imaging: status quo, challenges, and future opportunities.J Thorac Imaging. 2020; 35: S11-S16https://doi.org/10.1097/RTI.0000000000000499
- Precise and automatic patient positioning in computed tomography: avatar modeling of the patient surface using a 3-dimensional camera.Invest Radiol. 2018; 53: 641-646https://doi.org/10.1097/RLI.0000000000000482
- Accuracy of automated patient positioning in CT using a 3D camera for body contour detection.Eur Radiol. 2019; 29: 2079-2088https://doi.org/10.1007/s00330-018-5745-z
- A comparison between manual and artificial intelligence-based automatic positioning in CT imaging for COVID-19 patients.Eur Radiol. 2021 Aug; 31: 6049-6058
- Health protection of CT radiographers during the outbreak of COVID-19: application of automatic positioning technology for relocatable CT in the fang cang hospital.Front Med (Lausanne). 2021; 8659520
- Use of artificial intelligence in computed tomography dose optimisation.Ann ICRP. 2020; 49: 113-125https://doi.org/10.1177/0146645320940827
- Radiation dose reduction with hybrid iterative reconstruction for pediatric CT.Radiology. 2012; 263: 537-546https://doi.org/10.1148/radiol.12110268
- Dose reduction in pediatric abdominal CT: use of iterative reconstruction techniques across different CT platforms.Pediatr Radiol. 2015; 45: 1046-1055https://doi.org/10.1007/s00247-014-3235-2
- Deep learning for biomedical image reconstruction: a survey.Artif Intell Rev. 2021; 54: 215-251
- Deep learning for tomographic image reconstruction.Nat Mach Intell. 2020; 2: 737-748https://doi.org/10.1038/s42256-020-00273-z
- CD-Net: comprehensive domain network with spectral complementary for DECT sparse-view reconstruction.IEEE Trans Comput Imaging. 2021; 7: 436-447
- Domain progressive 3D residual convolution network to improve low-dose CT imaging.IEEE Trans Med Imaging. 2019; 38: 2903-2913https://doi.org/10.1109/TMI.2019.2917258
- CLEAR: comprehensive learning enabled adversarial reconstruction for subtle structure enhanced low-dose CT imaging.IEEE Trans Med Imaging. 2021; https://doi.org/10.1109/TMI.2021.3097808
- SPECIAL: single-shot projection error correction integrated adversarial learning for limited-angle CT.IEEE Transactions on Computational Imaging. 2021; 7: 734-746
- The use of artificial intelligence in computed tomography image reconstruction - A literature review.J Med Imaging Radiat Sci. 2020; 51: 671-677https://doi.org/10.1016/j.jmir.2020.09.001
- The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence.Eur Radiol. 2019; 29: 2185-2195https://doi.org/10.1007/s00330-018-5810-7
- Artificial intelligence and CT image reconstruction: potential of a new era in radiation dose reduction.J Am Coll Radiol. 2020; 17: 649-651https://doi.org/10.1016/j.jacr.2019.12.025
- Generative adversarial network in medical imaging: a review.Med Image Anal. 2019; 58101552https://doi.org/10.1016/j.media.2019.101552
- Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study.Eur Radiol. 2020; 30: 3951-3959https://doi.org/10.1007/s00330-020-06724-w
- Validation of deep-learning image reconstruction for low-dose chest computed tomography scan: emphasis on image quality and noise.Korean J Radiol. 2021; 22: 131-138https://doi.org/10.3348/kjr.2020.0116
- The potential for reduced radiation dose from deep learning-based CT image reconstruction: A comparison with filtered back projection and hybrid iterative reconstruction using a phantom.Medicine (Baltimore). 2021; 100: e25814https://doi.org/10.1097/MD.0000000000025814
- Deep learning reconstruction at CT: phantom study of the image characteristics.Acad Radiol. 2020; 27: 82-87https://doi.org/10.1016/j.acra.2019.09.008
- Deep learning reconstruction versus iterative reconstruction for cardiac CT angiography in a stroke imaging protocol: reduced radiation dose and improved image quality.Quant Imaging Med Surg. 2021; 11: 392-401https://doi.org/10.21037/qims-20-626
- Image quality and lesion detection on deep learning reconstruction and iterative reconstruction of submillisievert chest and abdominal CT.AJR Am J Roentgenol. 2020; 214: 566-573https://doi.org/10.2214/AJR.19.21809
- Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT.Eur Radiol. 2019; 29: 6163-6171https://doi.org/10.1007/s00330-019-06170-3
- Diagnostic value of deep learning reconstruction for radiation dose reduction at abdominal ultra-high-resolution CT.Eur Radiol. 2021; 31: 4700-4709https://doi.org/10.1007/s00330-020-07566-2
- Deep learning trained algorithm maintains the quality of half-dose contrast-enhanced liver computed tomography images: Comparison with hybrid iterative reconstruction: Study for the application of deep learning noise reduction technology in low dose.Eur J Radiol. 2021; 135109487https://doi.org/10.1016/j.ejrad.2020.109487
- Comparison of image quality and lesion diagnosis in abdominopelvic unenhanced CT between reduced-dose CT using deep learning post-processing and standard-dose CT using iterative reconstruction: a prospective study.Eur J Radiol. 2021; 139109735https://doi.org/10.1016/j.ejrad.2021.109735
- Artificial intelligence in image reconstruction: The change is here.Phys Med. 2020; 79: 113-125https://doi.org/10.1016/j.ejmp.2020.11.012
- Image Reconstruction is a New Frontier of Machine Learning.IEEE Trans Med Imaging. 2018; 37: 1289-1296https://doi.org/10.1109/TMI.2018.2833635
- A study of using a deep learning image reconstruction to improve the image quality of extremely low-dose contrast-enhanced abdominal CT for patients with hepatic lesions.Br J Radiol. 2021; 9420201086https://doi.org/10.1259/bjr.20201086
- Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters.Radiology. 2004; 232: 791-797https://doi.org/10.1148/radiol.2323031563
FDA Cleared AI Algorithms. American College of Radiology Data Science Institute. Accessed from: https://models.acrdsi.org/ Accessed on May 10, 2021]
- Application of vendor-neutral iterative reconstruction technique to pediatric abdominal computed tomography.Korean J Radiol. 2019; 20: 1358-1367https://doi.org/10.3348/kjr.2018.0715
- Iterative reconstruction and deep learning algorithms for enabling low-dose computed tomography in midfacial trauma [published online ahead of print, 2020 Dec 8].Oral Surg Oral Med Oral Pathol Oral Radiol. 2020; : 4522https://doi.org/10.1016/j.oooo.2020.11.018
- Potential value of the PixelShine deep learning algorithm for increasing quality of 70 kVp+ASiR-V reconstruction pelvic arterial phase CT images.Jpn J Radiol. 2019; 37: 186-190https://doi.org/10.1007/s11604-018-0798-0
- Imaging quality control in the era of artificial intelligence.J Am Coll Radiol. 2019; 16: 1259-1266https://doi.org/10.1016/j.jacr.2019.05.048
- Statistical issues in searches for new phenomena in high energy physics.J. Phys. G: Nucl. Part. Phys. 2018; 45033001
- Computed Tomography: Principles, Design, Artifacts, and Recent Advances.Third Edition. SPIE, 2015 (Chapter 5.2)
- Informatics in radiology: sliding-thin-slab averaging for improved depiction of low-contrast lesions with radiation dose savings at thin-section CT.Radiographics. 2010; 30: 317-326https://doi.org/10.1148/rg.302096007
- Hybrid iterative reconstruction technique for abdominal CT protocols in obese patients: assessment of image quality, radiation dose, and low-contrast detectability in a phantom.AJR Am J Roentgenol. 2014; 202: W146-W152https://doi.org/10.2214/AJR.12.10513
- CT detectability of small low-contrast hypoattenuating focal lesions: iterative reconstructions versus filtered back projection.Radiology. 2018; 289: 443-454https://doi.org/10.1148/radiol.2018180137
- Detection of colorectal hepatic metastases is superior at standard radiation Dose CT versus reduced dose CT.Radiology. 2019; 290: 400-409https://doi.org/10.1148/radiol.2018181657
- Effect of obesity on ability to lower exposure for detection of low-attenuation liver lesions.J Appl Clin Med Phys. 2021; 22: 138-144https://doi.org/10.1002/acm2.13149
- Rapid measurement of the low contrast detectability of CT scanners.Med Phys. 2021; 48: 1054-1063https://doi.org/10.1002/mp.14657
- Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: impact of radiation dose and reconstruction algorithms.Med Phys. 2013; 40041908https://doi.org/10.1118/1.4794498
- A signal detection model for quantifying overregularization in nonlinear image reconstruction [published online ahead of print, 2021 Jun 25].Med Phys. 2021; https://doi.org/10.1002/mp.14703
- Image quality assessment of abdominal CT by use of new deep learning image reconstruction: initial experience.AJR Am J Roentgenol. 2020; 215: 50-57https://doi.org/10.2214/AJR.19.22332
- Improving image quality and reducing radiation dose for pediatric CT by using deep learning reconstruction.Radiology. 2021; 298: 180-188https://doi.org/10.1148/radiol.2020202317
- Reproducibility of lung nodule radiomic features: multivariable and univariable investigations that account for interactions between CT acquisition and reconstruction parameters.Med Phys. 2021; 48: 2906-2919https://doi.org/10.1002/mp.14830
- Pneumonia detection in chest X-Ray dose-equivalent CT: impact of dose reduction on detectability by artificial intelligence.Acad Radiol. 2020; https://doi.org/10.1016/j.acra.2020.05.031
- Influence of CT effective dose and convolution kernel on the detection of pulmonary nodules in different artificial intelligence software systems: a phantom study.Eur J Radiol. 2020; 126108928https://doi.org/10.1016/j.ejrad.2020.108928
- Effect of scanning and reconstruction parameters on three dimensional volume and CT value measurement of pulmonary nodules: a phantom study.Zhongguo Fei Ai Za Zhi. 2017; 20: 562-567https://doi.org/10.3779/j.issn.1009-3419.2017.08.11
- Comparison of standard- and low-radiation-dose CT for quantification of emphysema.AJR Am J Roentgenol. 2007; 188: 42-47https://doi.org/10.2214/AJR.05.1498
- Radiomics in the evaluation of lung nodules: Intrapatient concordance between full-dose and ultra-low-dose chest computed tomography.Diagn Interv Imaging. 2021; 102: 233-239https://doi.org/10.1016/j.diii.2021.01.010
- DeepLN: an artificial intelligence-based automated system for lung cancer screening.Ann Transl Med. 2020; 8: 1126https://doi.org/10.21037/atm-20-4461
- The use of artificial intelligence in the differentiation of malignant and benign lung nodules on computed tomograms proven by surgical pathology.Cancers (Basel). 2020; 12: 2211https://doi.org/10.3390/cancers12082211
- Development and clinical application of deep learning model for lung nodules screening on CT images.Sci Rep. 2020; 10: 13657https://doi.org/10.1038/s41598-020-70629-3
- Artificial neural networks improve LDCT lung cancer screening: a comparative validation study.BMC Cancer. 2020; 20: 1023https://doi.org/10.1186/s12885-020-07465-1
- A 3D probabilistic deep learning system for detection and diagnosis of lung cancer using low-dose CT scans.IEEE Trans Med Imaging. 2020; 39: 1419-1429https://doi.org/10.1109/TMI.2019.2947595
- Prognostic value and reproducibility of AI-assisted analysis of lung involvement in COVID-19 on low-dose submillisievert chest CT: sample size implications for clinical trials.Radiol Cardiothorac Imaging. 2020; 2 (Published 2020 Oct 22)e200441https://doi.org/10.1148/ryct.2020200441
- Approval of artificial intelligence and machine learning-based medical devices in the USA and Europe (2015-20): a comparative analysis.Lancet Digit Health. 2021; 3: e195-e203https://doi.org/10.1016/S2589-7500(20)30292-2
- How medical AI devices are evaluated: limitations and recommendations from an analysis of FDA approvals.Nat Med. 2021; 27: 582-584https://doi.org/10.1038/s41591-021-01312-x
- Common pitfalls and recommendations for using machine learning to detect and prognosticate for COVID-19 using chest radiographs and CT scans.Nature Machine Intelligence. 2021; 3: 199-217https://doi.org/10.1038/s42256-021-00307-0
Dreyer KJ, Allen B, Wald C. Real-World Surveillance of FDA-Cleared Artificial Intelligence Models: Rationale and Logistics [published online ahead of print, 2021 Oct 2]. J Am Coll Radiol. 2021;S1546-1440(21)00733-X. doi:10.1016/j.jacr.2021.06.025.
- Current applications and future impact of machine learning in radiology.Radiology. 2018; 288: 318-328https://doi.org/10.1148/radiol.2018171820
- Assessment of diagnostic image quality of computed tomography (CT) images of the lung using deep learning.Proc. SPIE Medical Imaging. 2018; 105731https://doi.org/10.1117/12.2292070
- A deep learning approach to radiation dose estimation.Phys Med Biol. 2020; 65035007https://doi.org/10.1088/1361-6560/ab65dc
- A method of rapid quantification of patient-specific organ doses for CT using deep-learning-based multi-organ segmentation and GPU-accelerated Monte Carlo dose computing.Med Phys. 2020; 47: 2526-2536https://doi.org/10.1002/mp.14131
- Analysis of a CT patient dose database with an unsupervised clustering approach.Phys Med. 2019; 60: 91-99https://doi.org/10.1016/j.ejmp.2019.03.015
- Potential of a machine-learning model for dose optimization in CT quality assurance.Eur Radiol. 2019; 29: 3705-3713https://doi.org/10.1007/s00330-019-6013-6
- Sinogram-based deep learning image reconstruction technique in abdominal CT: image quality considerations.Eur Radiol. 2021; https://doi.org/10.1007/s00330-021-07952-4