Advertisement

Feasibility of 3D Breath-Hold MR Cholangiopancreatography with a Spatially Selective Radiofrequency Excitation Pulse: Prospective Comparison with Parallel Imaging Technique and Compressed Sensing Method

Published:March 31, 2022DOI:https://doi.org/10.1016/j.acra.2022.03.006

      Rationale and Objectives

      The purpose of the present study was to evaluate the clinical feasibility of the modified 3D breath-hold magnetic resonance cholangiopancreatography with parallel imaging (3D-BH-PI-MRCP) using a spatially selective radiofrequency excitation pulse in patients with suspected pancreaticobiliary diseases. Moreover, we also compared its image quality with those of the original 3D-BH-PI-MRCP with a nonselective exciting pulse and the 3D breath hold compressed sensing magnetic resonance cholangiopancreatography (3D-BH-CS-MRCP).

      Materials and Methods

      Between January 2021 and July 2021, 106 patients prospectively underwent modified 3D-BH-PI-MRCP, original 3D-BH-PI-MRCP and 3D-BH-CS-MRCP at 3T in this study. The Friedman test was performed to compare the contrast, signal-to-noise-ratio (SNR), and contrast-noise-ratio, overall image quality, and duct visualization among the three protocols.

      Results

      The contrast ratio, SNR and contrast-to-noise ratio of the common bile duct differed significantly among the three sequences (p < 0.001). Compared to the 3D-BH-CS-MRCP protocol, the overall imaging quality of the two 3D-BH-PI-MRCP was higher but not significantly different. The scores for the anterior and posterior branches visualization were significantly higher in the original 3D-BH-PI-MRCP compared to the 3D-BH-CS-MRCP, but were no significant differences between the modified 3D-BH-PI-MRCP and the 3D-BH-CS-MRCP.

      Conclusion

      The modified 3D-BH-PI-MRCP with a spatially selective radiofrequency excitation pulse could provide comparable image quality to the original 3D-BH-PI-MRCP and the 3D-BH-CS-MRCP during a single breath hold (22 seconds), and showed improved SNR and superior visualization of the pancreaticobiliary tree.

      Key Words

      Abbreviations:

      MRCP (magnetic resonance cholangiopancreatography), BH (breath-hold), NT (navigator-triggered), SPACE (sampling perfection with application optimized contrasts using different flip angle evolutions), CNR (contrast-to-noise ratio), SNR (signal-to-noise ratio), 3D (three-dimensional), PI (parallel imaging), CS (compressed sensing)
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Academic Radiology
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Cai L
        • Yeh BM
        • Westphalen AC
        • et al.
        3D T2-weighted and Gd-EOB-DTPA-enhanced 3D T1-weighted MR cholangiography for evaluation of biliary anatomy in living liver donors.
        Abdom Radiol. 2016; 42: 842-850
        • Nakaura T
        • Kidoh M
        • Maruyama N
        • et al.
        Usefulness of the SPACE pulse sequence at 1.5T MR cholangiography: Comparison of image quality and image acquisition time with conventional 3D-TSE sequence.
        J Magn Reson Imaging. 2013; 38: 1014-1019
        • Zhang J
        • Israel GM
        • Hecht EM
        • et al.
        Isotropic 3D T2-weighted MR cholangiopancreatography with parallel imaging: feasibility study.
        AJR Am J Roentgenol. 2006; 187: 1564-1570
        • Asbach P
        • Dewey M
        • Klessen C
        • et al.
        Respiratory-triggered MRCP applying parallel acquisition techniques.
        J Magn Reson Imaging. 2006; 24: 1095-1100
        • Masui T
        • Katayama M
        • Kobayashi S
        • et al.
        Magnetic resonance cholangiopancreatography: comparison of respiratory-triggered three dimensional fast-recovery fast spin-echo with parallel imaging technique and breath-hold half-Fourier two-dimensional single-shot fast spin-echo technique.
        Radiat Med. 2006; 24: 202-209
        • Nandalur KR
        • Hussain HK
        • Weadock WJ
        • et al.
        Possible biliary disease: diagnostic performance of high-spatial-resolution isotropic 3D T2-weighted MRCP.
        Radiology. 2008; 249: 883-890
        • Chen Z
        • Sun B
        • Duan Q
        • et al.
        Three-dimensional breath-hold MRCP using SPACE pulse sequence at 3 T: comparison with conventional navigator-triggered technique.
        AJR Am J Roentgenol. 2019; 213: 1247-1252
        • Zhu L
        • Xue H
        • Sun Z
        • et al.
        Modified breath-hold compressed-sensing 3D MR cholangiopancreatography with a small field-of-view and high resolution acquisition: clinical feasibility in biliary and pancreatic disorders.
        J Magn Reson Imaging. 2018; 48: 1389-1399
        • Mannes I
        • Dallongeville A
        • Badat N
        • et al.
        Breath-hold compressed-sensing 3D MR cholangiopancreatography compared to free-breathing 3D MR cholangiopancreatography: prospective study of image quality and diagnostic performance in pancreatic disorders.
        Abdom Radiol (NY). 2020; 45: 1082-1091
        • Yoshida Morikatsu
        • Nakaura Takeshi
        • Inoue Taihei
        • et al.
        Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: does it improve image quality and acquisition time as compared with 3D TSE.
        Eur. Radiol. 2018; 28: 2436-2443
        • Seo N
        • Park MS
        • Han K
        • et al.
        Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3 T.
        J Magn Reson Imaging. 2017; 46: 1289-1297
        • Zhu L
        • Wu X
        • Sun Z
        • et al.
        Compressed-sensing accelerated 3-dimensional magnetic resonance cholangiopancreatography: application in suspected pancreatic diseases.
        Invest Radiol. 2018; 53: 150-157
        • Yoon JH
        • Lee SM
        • Kang HJ
        • et al.
        Clinical feasibility of 3-dimensional magnetic resonance cholangiopancreatography using compressed sensing: comparison of image quality and diagnostic performance.
        Invest Radiol. 2017; 52: 612-619
        • Yokoyama K
        • Nakaura T
        • Iyama Y
        • et al.
        Usefulness of 3D hybrid profile order technique with 3T magnetic resonance cholangiography: comparison of image quality and acquisition time.
        J Magn Reson Imaging. 2016; 44: 1346-1353
        • Nam JG
        • Lee JM
        • Kang HJ
        • et al.
        GRASE Revisited: breath-hold three-dimensional (3D) magnetic resonance cholangiopancreatography using a Gradient and Spin Echo (GRASE) technique at 3 T.
        Eur Radiol. 2018; 28: 3721-3728
        • Itatani Ryo
        • Namimoto Tomohiro
        • Kusunoki Shinichiro
        • et al.
        Usefulness of the short-echo time cube sequence at 3-T magnetic resonance cholangiopancreatography: prospective comparison with the conventional 3-dimensional fast spin-echo sequence.
        J Comput Assist Tomogr. 2016; 40: 551-556
        • Yoen H
        • Lee JM
        • Lee SM
        • et al.
        Comparisons between image quality and diagnostic performance of 2D- and breath-hold 3D magnetic resonance cholangiopancreatography at 3T.
        Eur Radiol. 2021; https://doi.org/10.1007/s00330-021-07968-w
        • He M
        • Xu J
        • Sun Z
        • et al.
        Comparison and evaluation of the efficacy of compressed SENSE (CS) and gradient- and spin-echo (GRASE) in breath-hold (BH) magnetic resonance cholangiopancreatography (MRCP).
        J Magn Reson Imaging. 2020; 51: 824-832
        • Chen Z
        • Sun B
        • Xue Y
        • et al.
        Comparing compressed sensing breath-hold 3D MR cholangiopancreatography with two parallel imaging MRCP strategies in main pancreatic duct and common bile duct.
        Eur J Radiol. 2021; 142https://doi.org/10.1016/j.ejrad.2021.109833